CG170-20 Gas Generator Set

US
Metric

Overview

Generator Set Specifications

Maximum Continuous Rating
2000 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas

Gas Generator Sets Specification

Maximum Electrical Efficiency
43.7%
Maximum Standby Rating
2000

Generator Set Specifications

Frequency
50 / 60 Hz
RPM
1500

Engine Specification

Engine Model
CG170-20

Engine Specifications

Bore
6.70 in
170.00 mm
Stroke
7.70 in
195.00 mm
Displacement
3240.00 in³
53.10 l
Aspiration
TA

Generator Set Dimensions

Length
294.00 in
7467.60 mm
Width
67.00 in
1710.00 mm
Height
86.00 in
2190.00 mm
Dry Weight - Genset
43651.10 lb
19800.00 kg

Generator Set Specifications

Maximum Electrical Efficiency
43.70%
Maximum Standby Rating
2000

Engine Specifications

Engine Model
CG170-20
Aspiration
TA
Features

High Efficiency, Lower Operating Costs

  • Miller cycle timing with combustion chamber and spark plug improvement help on saving up to 15% fuel gas per year
  • CG170 (non-miller) is optimized for Island-Mode capability
  • Gearbox helps limit wear and tear on engine components, lowering operating costs and increasing availability

Low installation, Building and Operating Costs

  • Extended maintenance intervals thanks to sooth-free combustion and enlarged oil tank
  • Low fuel consumption due to improved combustion chamber and pre-chamber spark-plugs
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
  • Optimized oil management

Optimized Lubrication Consumption

  • Consumes up to 1900 liter less lube oil per year than comparable models<\li>
  • Longer lubricant change and oil change intervals<\li>
Standard Equipment
  • Air Inlet
    • Turbocharger with a water-cooled bearing case for all cylinder
    • One-element single-stage air cleaner with enclosure and sevice indicator
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • Jacket water and SCAC thermostats
    • flange connections for JW inlet and outlet
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
    • Exhaust waste gate for the CG170-20
  • Fuel system
    • Pre-chamber spark plugs
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
  • Generator
    • Winding temperature detectors
    • 3-phase sensing and KVAR/PF control
    • Reactive droop
    • closed-coupled generator result in no torque transmission to the base frame
    • grid code generator
    • Anti-condensation space heater
    • Busbar connections
  • Starting/Charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard
Optional Equipment
  • Cooling
    • CHP skid